Significance and Use
4.1 This test method is well suited for measuring the viscosity of glasses between the range within which rotational viscometry (see Practice C965) is useful and the range within which beam bending viscometry is useful (see Test Method C1350M). It can be used to determine the viscosity/temperature curve in the region near the softening point (see Test Method C338). This test method is useful for providing information related to the behavior of glass as it is formed into an object of commerce, and in research and development.
Scope
1.1 This test method covers the determination of the viscosity of glass from 104 Pa·s to 108 Pa·s by measuring the rate of viscous compression of a small, solid cylinder.2