• Skip to main content
  • Skip to header right navigation
  • Skip to site footer

1-800-685-2088 | support@mat-cs.com

  • LinkedIn
MAT-CS - Materials Characterization Services

Materials Characterization Services

  • Home
  • About
    • Meet the Team
    • Consulting
  • Analytical Techniques
    • Bulk Analysis
    • Microscopy and Microanalytical
    • Surface and Thin Film
    • Polymer Characterization
    • Optical Measurements
    • Liquids and Gases
    • Electrical / Electronics
    • Reliability Testing
    • Miscellaneous
  • Test Methods
    • ASTM Methods List
    • ISO Methods List
    • AATCC
    • AOAC
    • AOCS
    • EPA, SM
    • FDA BAM
    • IP
    • JEDEC
    • MIL-STD
    • OCSPP
    • OPPTS
    • REACH
    • RoHS
    • SEMI
    • TAPPI
    • USP/EP/JP
  • Resources
    • Experiment Design
    • Consulting
    • The Laboratory Landscape
    • Quality Programs
    • Regulatory-Based Analyses
  • Contact
  • Get a Quote!
MAT-CS Home Cover

ASTM C476

ASTM C476 – Standard Specification for Grout for Masonry

Description:

Abstract

This specification covers two types of grout, fine and coarse grout, for use in the construction of masonry structures. Grout is specified by proportions or strength requirements. Materials used as ingredients in grout shall conform to the requirements specified such as: cementitious materials; blended cements; quicklime; hydrated lime; coal fly ash or raw calcine natural pozzolan; granulated blast furnace slag; air-entraining admixtures; aggregates; water; pumping aids; antifreeze compounds; and storage of materials. Fine grout shall be manufactured with fine aggregates. Coarse grout shall be manufactured with a combination of coarse and fine aggregates. Proportions of ingredients shall be determined by grout proportion requirements and by the specified compressive strength. Materials for grout shall be measured in such a way that the required proportions of the grout materials are controlled and accurately measured. Grout shall be produced using one of the following procedures: grout materials mixed with water at the job site and ready-mixed grout transported to the job site.

Scope

1.1 This specification covers two types of grout, fine and coarse grout, for use in the construction of masonry structures. Each type (fine and coarse) is further classified as conventional grout (requiring mechanical consolidation by puddling or vibration when placed) and self-consolidating grout (not requiring mechanical consolidation when placed). Conventional grout is specified by (1) proportions or (2) strength requirements. Self-consolidating grout is specified by strength requirements.

1.2 The text of this specification references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Related Test Methods

ASTM D4865

ASTM D4860

ASTM D4857

ASTM D4850

ASTM D4839

ASTM D4833

ASTM D483

ASTM D4829

ASTM D4828

ASTM D4824

ASTM D482

ASTM D4815

Previous Post:MAT-CS Home CoverASTM C473
Next Post:ASTM C480MAT-CS Home Cover

Ready to start your analysis?

Get a Quote!
MAT-CS

Your One Source for Materials Analysis

1-800-685-2088

support@mat-cs.com

  • Home
  • Analytical Techniques
  • Test Methods
  • Resources
  • Contact Us
  • Get a Quote!
  • Special Analysis Request

  • LinkedIn

Copyright © 2025 by Materials Characterization Services ยท All Rights Reserved
Website Built, Hosted, and Managed by Digital Donkey Marketing