ASTM D1186 – Standard Test Methods for Nondestructive Measurement of Dry Film Thickness of Nonmagnetic Coatings Applied to a Ferrous Base (Withdrawn 2006)
Description:
Scope
1.1 These test methods cover the nondestructive measurement of the dry film thickness of nonmagnetic coatings applied over a ferrous base material using commercially available test instruments. The test methods cover the use of instruments based on magnetic measuring principles only. Test Method A provides for the measurement of films using magnetic pull-off gages and Test Method B provides for the measurement of films using magnetic flux gages.
1.2 These test methods are not applicable to coatings that will be readily deformable under the load of the measuring instruments, as the instrument probe must be placed directly on the coating surface to take a reading.
1.3 The values given in SI units of measurement are to be regarded as the standard. The values in parentheses are for information only.