ASTM D5028 – Standard Test Method for Curing Properties of Pultrusion Resins by Thermal Analysis
Description:
Significance and Use
5.1 Differential scanning calorimeters are used to determine chemical reaction thermal profiles of materials. One such reaction is the curing of thermosetting resins.
5.2 This test method is useful for both specification acceptance and for research.
Scope
1.1 This test method covers determination of curing parameters of pultrusions resins by differential scanning calorimetry.
1.2 This test method is applicable to pultrusion resin solutions with adequate initiator(s).
1.3 The normal operating temperature range is from 0 to 200°C.
Note 1: Resin systems that do not form an adequate baseline are not covered by this test method.
1.4 Computer or electronic based instruments or data treatment equivalent to this practice are suitable for use.
1.5 The values stated in SI units are to be regarded as standard.